SPECIAL MOBILE / MANUFACTURED HOME
REQUIREMENTS
WARNING: Do not install in a sleeping room.
For installation in a mobile/manufactured home, the
outside air kit must be used.
(SeeOUTSIDE AIR KIT W3000FS ONLY”)
The W3000FS must be securely fastened to the floor
of the mobile (manufactured) home using the
mounting bolt holes located in the pedestal of the
W3000FS. Use only the holes provided.
If the optional blower is used the W3000FS must be
grounded to the steel chassis of the home with 8 Ga.
Copper wire using a serrated or star washer to
penetrate paint or protective coating to ensure
grounding.
WARNING: DURING THE INSTALLATION OF THIS
STOVE, DO NOT COMPROMISE THE
STRUCTUARL INTEGRITY OF THE MOBILE
(MANUFACTURED) HOME WALL(S), FLOOR OR
CEILING.
INSTALLING THE BRICK PANELS
The brick panels will come already installed in the
W3000. The following directions are included should
you ever need to remove and re-install the brick
panels.
Wearing gloves is recommended when handling the
brick panels.
Install the brick panels shown in figure 6 in the
following order: C, A (rear), D, A (bottom). Next install
the ‘B’ panels on the secondary tubes.
(See figures 7 & 8)
INSTALLATION
9
FIGURE 6
FIGURE 7
FIGURE 8
BRICK SIZES
A = 10” x 12”
B = 9-3/4” x 15-1/4”
C = 9” x 7-7/8”
D =
2
-
7/8” x 2
0”
Vue de la page 8